The Update Manager 5. For information about new vCenter Server features, requirements, and installation, see the VMware vSphere 5. This release contains bug fixes described in Resolved Issues and known issues described in Known Issues.

Minimum hardware requirements for Update Manager vary depending on how Update Manager is deployed. If the database is installed on the same machine as Update Manager, requirements for memory size and processor speed are higher.

The minimum requirements to ensure acceptable performance are as follows:. The sizing estimator calculates the size of the Update Manager database and patch store. The estimate is calculated from the information that you enter about your deployment, such as the number of the hosts and virtual machines.

The sizing estimator also provides recommendations for the Update Manager database and server deployment models. Each installation of vSphere Update Manager must be associated with a single vCenter Server instance. The Update Manager module consists of a server component and client component. The Update Manager server can be installed on the same system as vCenter Server or on a different system.

The Update Manager provides two client components: Before you install Update Manager, you must install vCenter Server. You can use Update Manager Web Client for viewing scan results and compliance states for vSphere inventory objects. The Update Manager Client provides you with the full set of capabilities you need to perform patch and version management for your vSphere inventory. Install UMDS in case your deployment system is secured and the machine on which Update Manager is installed has no access to the Internet.

In the UMDS 5. You should uninstall existing UMDS 4. After you associate an existing download directory with UMDS 5. You should not install UMDS 5. In such a case, you need an UMDS 4. For more information about reconfiguring the Update Manager settings by using the utility, see the Reconfiguring VMware vSphere Update Manager documentation.

This release allows upgrades from Update Manager versions 4. Direct upgrades from Update Manager 1. You must use the data migration tool that is provided with Update Manager 5. In addition, check this site for information about supported management and backup agents before installing ESXi or vCenter Server. You cannot log in to Update Manager Utility after updating the certificates for your vSphere environment If you replace the certificates of the components in your vSphere environment, you cannot log in to the Update Manager Utility, and the following error message appears: Failed to run vciInstallUtility.

This issue is resolved in this release. If you select the Update Manager tab in vSphere Web Client after uninstalling the Update Manager server, the following error message appears: Log out and log in to the vSphere Web Client. Attempts to install the Update Manager server and UMDS with the bundled database fail on Windows operating system with Turkish language pack On Windows operating systems with Turkish language pack, attempts to install the Update Manager server and UMDS with the bundled database fail with the following error: Setup failed to create database tables.

To work around the issue, perform one of the following tasks: After an upgrade, the Update Manager plug-in might be disabled for the duration of a download task If Update Manager loses connection to vCenter Server while a download task is running, the Update Manager plug-in cannot be re-enabled. This problem might occur after an upgrade of Update Manager.

Wait for the download task to complete, and then enable the Update Manager plug-in. After you upgrade from Update Manager 1. If you click No , the following error message appears: Specified argument was out of the range of valid values. You might encounter this problem after you upgrade Update Manager 1.

When the dialog box prompts you to save the changes, click Yes. Database temporarily unavailable or has network problems. Parallel hosts remediation fails in Virtual SAN clusters The host remediation process fails if you selected the option to remediate hosts in parallel in a Virtual SAN cluster.

A host cannot enter maintenance mode while other hosts in the Virtual SAN cluster are currently in maintenance mode. During staging or remediation of patches a wrong warning message might appear During patch staging or remediation operations in Update Manager, you might be incorrectly warned that some patches are not available. The warning message you receive is: Some of the patches you selected for remediation are not available.

Do you want to continue? Ignore the message, and click Yes to proceed with staging. All patches that you initially selected will be staged. Starting with vSphere 5. When a VIB is installed or updated on an ESXi host, a flag is set to signify that the bootbank on the host has been updated. Update Manager checks for this flag while performing an upgrade scan or remediation and requires this flag to be cleared before upgrading a host.

The flag can be cleared by rebooting the host. Reboot hosts that report the compliance status as Incompatible. Run the upgrade scan or remediation again after the host is back online. Remediation of ESX 4. When you remediate an ESX 4. Verify that the ESXi 4. The target host does not support the virtual machine's current hardware requirements.

For incompatibilities other than cpuid. Requirements were not met for the following features: See the error stack for details on the cause of this problem. Ignore the error message.

When you use the Remediate wizard, you can ignore some upgrade scan warnings and force a remediation even if the upgrade warnings are not related to third-party software On the ESXi 5. Selecting the option also forces Update Manager to ignore three potential issues that are not related to third-party software.

The following warning messages are associated with the potential issues. The root password is encrypted with DES encryption, causing it to be authenticated up to only 8 characters. For instructions on how to correct this, see VMware KB at http: This configuration is not supported after upgrade.

Before remediation, perform an upgrade scan and review the messages in the Upgrade Details window of Update Manager. Take the necessary actions recommended in the messages to ensure that the remediation succeeds. The information about whether a reboot is required is contained in the update metadata and is displayed in the Update Manager Patch Repository, under Impact.

This provides reboot optimization for some VIBs, where an initial installation does not require a host reboot and only subsequent patching of the VIB requires a reboot. No workaround is required. Update Manager reboots hosts as necessary to ensure a successful remediation.

Host patch remediation fails when patch metadata is not available In the Update Manager installation wizard, you can deselect Download updates from default sources immediately after installation. Download patch metadata for all host versions you have in your inventory. Compliance status is Incompatible and remediation fails for ESX 4. The remediation of ESX 4. The scan and remediation problems are caused by third-party drivers in the ESX 4.

After an upgrade scan of hosts, more information about third-party software is provided in the conflict details for the upgrade baseline. Two different types of drivers might cause the problems. Async drivers, for example oem-vmware-esx-drivers-scsi-3w-9xxx. The vendor releases drivers asynchronously for ESXi 5. If you require such drivers, you must download them, use Image Builder CLI to build a custom ESXi image that contains them, and remediate against the custom image.

Without the ESXi 5. Deprecated drivers, for example oem-vmware-esx-drivers-net-vxge. The driver is discontinued in ESXi 5. You should be aware of the functional implications of third-party software removal, because pertinent hardware devices might stop functioning. Host remediation might not complete if the host contains powered on fault tolerant virtual machines Host remediation might not complete if there are any Primary virtual machines with disabled FT on the host, and you select Fail Task or Retry on the Host Remediation Options page of the Remediate wizard.

In such a scenario, powered on Primary virtual machines with disabled FT cannot be powered off or migrated in a DRS cluster. The host cannot enter maintenance mode while there are powered on virtual machines on it, and the remediation cannot be completed. When you remediate hosts containing Primary or Secondary virtual machines, you can use one of the following workarounds: Manually migrate the fault tolerant virtual machine to another host before you start a remediation.

This is possible only if DRS is not disabled on the particular host. Host remediation might fail if vCenter Server does not properly update the power state of the host When a host is being powered on or exiting standby mode, the host power state might not get updated in vCenter Server and host remediation cannot finish or times out.

umds cannot  patch definitions

Fix – vSphere Update Manager fails to download patches

In such a scenario, powered on Primary virtual machines with disabled FT cannot be powered off or migrated in a DRS cluster. Host remediation might fail for some patches because of irresolvable conflict with the patches on the host Patch remediation of a host might fail when a patch for example, patch A in a baseline input conflicts with the host and the conflict cannot be resolved by the other patches in the baseline input. Verify that the ESXi 4. In such a case, you need an UMDS 4. The Remediation Selection page might display an incorrect number of patches for the selected baselines When you remediate a vSphere inventory object against a patch or extension baseline preselected in Compliance view, the initial page of the remediation wizard might show an incorrect number of patches that need to be remediated. Reboot hosts that report the compliance status as Incompatible. The Remediation Selection page might display an incorrect number of patches for the selected baselines When you remediate a vSphere inventory object against a patch or extension baseline preselected in Compliance view, the initial page of the remediation wizard might show an incorrect number of patches that need to be remediated.

VMware vSphere Update Manager 6.0 Update 1 Release Notes

VUM will not use system proxy settings you need to configure the proxy in the Update Manager manually, also ensure that you set the correct user account with proxy access etc. After installation, on the Configuration tab, you can choose to download only patch metadata from sources for specific ESXi versions, for example, only patch metadata for ESXi 5. Host upgrade scan and remediation might fail if there is not enough free space on the host Host upgrade scan and remediation might fail with the AgentInstallFailed error message. In the Run window, type regedit and press Enter. When you use the Remediate wizard, you can ignore some upgrade scan warnings and force a remediation even if the upgrade warnings are not related to third-party software On the ESXi 5. The target host does not support the virtual machine's current hardware requirements. I hope this helps. One of these tasks is Remediate Entity. You might be unable to view compliance information for a cloned virtual machine When you clone a virtual machine, enable Fault Tolerance for the machine, and power on the cloned virtual machine, you might not be able to view compliance information.

umds cannot  patch definitions

The Update Manager 5. This option is not supposed to be exposed. This release contains bug fixes described in Resolved Issues and known issues described in Known Issues. Compliance state information inconsistencies might appear on Update Manager Web Client page When you select a baseline in Update Manager Web Client, you see compliance state information for the object in the Attached Baselines table, the Attached Baseline Groups drop-down menu, and compliance state details under the Attached Baselines table. The Update Manager module consists of a client component, which is a plug-in interface to a VMware vSphere Client instance, and a server component that can be installed on the same system as vCenter Server or on a different system. Not a big issue if you are going to be using the default VMware download sources, however it might be more of an issue if using custom download sources. This content has been marked as final. The flag can be cleared by rebooting the host.